{"id":782,"date":"2025-12-31T18:23:12","date_gmt":"2026-01-01T00:23:12","guid":{"rendered":"https:\/\/plumbing101.i234.me\/wordpress\/?p=782"},"modified":"2026-05-16T05:15:21","modified_gmt":"2026-05-16T10:15:21","slug":"navicirc-setup-do-you-need-an-extra-pump","status":"publish","type":"post","link":"https:\/\/plumbing101.i234.me\/wordpress\/navicirc-setup-do-you-need-an-extra-pump\/","title":{"rendered":"NaviCirc Setup: Do You Need an Extra Pump?"},"content":{"rendered":"<p>You have a Navien tankless water heater.<\/p>\n<p>You want to add a NaviCirc recirculation valve.<\/p>\n<p>You also want faster hot water at the tap.<\/p>\n<p>Your home is new and single-level.<\/p>\n<p>It is about 100 feet from end to end.<\/p>\n<p>The heater is about 30 feet from one end.<\/p>\n<p>The kitchen and laundry sit near the middle.<\/p>\n<p>The master bath is near the other end.<\/p>\n<h2>Quick Q&amp;A<\/h2>\n<p><strong>Q: Should I use two NaviCirc valves in one house?<\/strong><\/p>\n<p><strong>A: Start with one valve at the farthest high-use fixture. Two valves can cause extra crossover and warmer \u201ccold\u201d water.<\/strong><\/p>\n<h2>What the NaviCirc valve really does<\/h2>\n<p>NaviCirc is a \u201ccrossover\u201d style valve.<\/p>\n<p>It connects hot and cold under one sink.<\/p>\n<p>It uses the cold line as a return path.<\/p>\n<p>This can cut the wait for hot water.<\/p>\n<p>It can also warm the cold line for a short time.<\/p>\n<p>The valve shuts down as it warms up.<\/p>\n<p>That helps limit heat bleed into the cold line.<\/p>\n<figure id=\"attachment_827\" aria-describedby=\"caption-attachment-827\" style=\"width: 300px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-827\" src=\"https:\/\/plumbing101.i234.me\/wordpress\/wp-content\/uploads\/2025\/12\/NaviCirc-Setup-Do-You-Need-an-Extra-Pump-300x200.png\" alt=\"NaviCirc Setup: Do You Need an Extra Pump?\" width=\"300\" height=\"200\" srcset=\"https:\/\/plumbing101.i234.me\/wordpress\/wp-content\/uploads\/2025\/12\/NaviCirc-Setup-Do-You-Need-an-Extra-Pump-300x200.png 300w, https:\/\/plumbing101.i234.me\/wordpress\/wp-content\/uploads\/2025\/12\/NaviCirc-Setup-Do-You-Need-an-Extra-Pump-1024x683.png 1024w, https:\/\/plumbing101.i234.me\/wordpress\/wp-content\/uploads\/2025\/12\/NaviCirc-Setup-Do-You-Need-an-Extra-Pump-768x512.png 768w, https:\/\/plumbing101.i234.me\/wordpress\/wp-content\/uploads\/2025\/12\/NaviCirc-Setup-Do-You-Need-an-Extra-Pump.png 1536w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><figcaption id=\"caption-attachment-827\" class=\"wp-caption-text\">NaviCirc Setup: Do You Need an Extra Pump?<\/figcaption><\/figure>\n<h2>Do you really need an external pump?<\/h2>\n<p>It depends on your exact Navien model.<\/p>\n<p>Some Navien \u201cA\u201d models have a built-in pump.<\/p>\n<p>Those models can run recirculation without an extra pump.<\/p>\n<p>Other models may need an external recirculation pump.<\/p>\n<p>This is common on units without an internal pump.<\/p>\n<p>It is also common on non-Navien heaters.<\/p>\n<h2>How to choose an external recirculation pump<\/h2>\n<p>Pick a pump made for domestic hot water.<\/p>\n<p>Use bronze or stainless steel materials for potable water.<\/p>\n<p>Avoid cast-iron pumps on drinking water lines.<\/p>\n<p>Size the pump for your loop and fittings.<\/p>\n<p>The NaviCirc valve is a low-flow device.<\/p>\n<p>It is meant to pass about 0.5 to 1.0 GPM.<\/p>\n<p>Use the NaviCirc manual specs as your baseline.<\/p>\n<p>It calls for a pump with about 15 to 23 feet of max head.<\/p>\n<p>That helps the valve work as intended.<\/p>\n<p>Here are two example pump families to compare.<\/p>\n<ul>\n<li><a href=\"https:\/\/www.tacocomfort.com\/product\/0015e3-ecm-high-efficiency-circulator\/\" target=\"_blank\" rel=\"noopener\">Taco 0015e3 (stainless option)<\/a><\/li>\n<li>Grundfos UPSe 15-58 family<\/li>\n<\/ul>\n<p>Match the pump to your pipe size and layout.<\/p>\n<p>Also, match your power and control method.<\/p>\n<p>Many owners prefer on-demand control.<\/p>\n<p>This can save energy and reduce cold-line warming.<\/p>\n<h2>Where to install the valve in a long ranch home<\/h2>\n<p>NaviCirc works best at the farthest fixture.<\/p>\n<p>That usually gives the best whole-home coverage.<\/p>\n<p>But your farthest fixture may be low use.<\/p>\n<p>So pick the farthest fixture you use often.<\/p>\n<p>In many homes, that is the master bath sink.<\/p>\n<p>This keeps your daily wait time low.<\/p>\n<p>It also keeps the guest side simpler.<\/p>\n<p>If the guest bath is rarely used, one valve is enough.<\/p>\n<p>If you need faster hot water in two zones, consider demand control.<\/p>\n<p>Demand systems run only when you ask for hot water.<\/p>\n<ul>\n<li><a href=\"https:\/\/www.navieninc.com\/accessories\/navicirc\" target=\"_blank\" rel=\"noopener\">Navien: NaviCirc overview<\/a><\/li>\n<li><a href=\"https:\/\/www.navieninc.com\/accessories\/hotbutton\" target=\"_blank\" rel=\"noopener\">Navien: HotButton on-demand recirculation<\/a><\/li>\n<li><a href=\"https:\/\/www.energystar.gov\/products\/demand-hot-water-recirculating-system\" target=\"_blank\" rel=\"noopener\">ENERGY STAR: Demand hot water recirculation<\/a><\/li>\n<\/ul>\n<h2>One more sizing detail to remember<\/h2>\n<p>Pipe length matters more than house length.<\/p>\n<p>Turns, tees, and valves add friction loss.<\/p>\n<p>Navien also lists equivalent length limits in the manual.<\/p>\n<p>That is one reason to keep the loop simple.<\/p>\n<h2>Bottom line<\/h2>\n<p>First, confirm if your Navien has a built-in pump.<\/p>\n<p>If it does, you may not need an external pump.<\/p>\n<p>If you do need a pump, use bronze or stainless.<\/p>\n<p>Then place one valve at the farthest high-use fixture.<\/p>\n<p>Use demand control if you want tighter control.<\/p>\n<p>I&#8217;m Chris Mayer, writing for <a href=\"https:\/\/plumbing101.i234.me\">Plumbing 101<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>You have a Navien tankless water heater. You want to add a NaviCirc recirculation valve. You also want faster hot water at the tap. Your home is new and single-level. It is about 100 feet from end to end. The heater is about 30 feet from one end. The kitchen and laundry sit near the&hellip; <a class=\"more-link\" href=\"https:\/\/plumbing101.i234.me\/wordpress\/navicirc-setup-do-you-need-an-extra-pump\/\">Continue reading <span class=\"screen-reader-text\">NaviCirc Setup: Do You Need an Extra Pump?<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":827,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_wpscp_schedule_draft_date":"","_wpscp_schedule_republish_date":"","_wpscppro_advance_schedule":false,"_wpscppro_advance_schedule_date":"","_wpscppro_dont_share_socialmedia":null,"_wpscppro_custom_social_share_image":0,"_facebook_share_type":"default","_twitter_share_type":"default","_linkedin_share_type":"default","_pinterest_share_type":"default","_linkedin_share_type_page":"","_instagram_share_type":"default","_medium_share_type":"default","_threads_share_type":"default","_google_business_share_type":"default","_selected_social_profile":[],"_wpsp_enable_custom_social_template":false,"_wpsp_social_scheduling":{"enabled":false,"datetime":null,"platforms":[],"status":"template_only","dateOption":"today","timeOption":"now","customDays":"","customHours":"","customDate":"","customTime":"","schedulingType":"absolute"},"_wpsp_active_default_template":true},"categories":[79],"tags":[847,850,846,929,109,111,855,848,931,844,853,843,845,107,852,115,918,854,930,851,849,412],"class_list":["post-782","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general-plumbing-help","tag-comfortflow-recirculation","tag-crossover-recirculation-valve-placement","tag-external-recirculation-pump-for-navien","tag-extra","tag-general","tag-help","tag-hot-water-recirc-cold-line-warming","tag-hot-water-recirculation-without-return-line","tag-navicirc","tag-navicirc-recirculation-valve","tag-navien-hotbutton-kit","tag-navien-navicirc","tag-navien-tankless-recirculation-pump","tag-need","tag-on-demand-hot-water-recirculation","tag-plumbing","tag-pump","tag-recirculation-pump-bronze-stainless","tag-setup","tag-single-story-hot-water-wait-time","tag-thermal-bypass-valve-under-sink","tag-you","entry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/plumbing101.i234.me\/wordpress\/wp-json\/wp\/v2\/posts\/782","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/plumbing101.i234.me\/wordpress\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/plumbing101.i234.me\/wordpress\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/plumbing101.i234.me\/wordpress\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/plumbing101.i234.me\/wordpress\/wp-json\/wp\/v2\/comments?post=782"}],"version-history":[{"count":3,"href":"https:\/\/plumbing101.i234.me\/wordpress\/wp-json\/wp\/v2\/posts\/782\/revisions"}],"predecessor-version":[{"id":1586,"href":"https:\/\/plumbing101.i234.me\/wordpress\/wp-json\/wp\/v2\/posts\/782\/revisions\/1586"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/plumbing101.i234.me\/wordpress\/wp-json\/wp\/v2\/media\/827"}],"wp:attachment":[{"href":"https:\/\/plumbing101.i234.me\/wordpress\/wp-json\/wp\/v2\/media?parent=782"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/plumbing101.i234.me\/wordpress\/wp-json\/wp\/v2\/categories?post=782"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/plumbing101.i234.me\/wordpress\/wp-json\/wp\/v2\/tags?post=782"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}